A 5 HP

Article: 00002405

Waterdraw trailer for calibrating bidirectional provers

The Seraphin waterdraw system has bottom drain stainless steel provers and one top drain measure mounted on top of a stainless steel water reservoir. Through the process of gravity ,the provers drain into the reservoir. A portable quick-connect hose with a 5 HP pump suctions the bottom of the reservoir tank and discharges into an inlet fitted on the customer's dynamic pipe prover. The customer's pipe prover through its discharge side is connected to a stainless steel manifold plumbed to the top neck of each prover. The system's many combinations can be used to calibrate different size pipe provers. At the inlet of the waterdraw manifold a solenoid operated valve connects to the detector switches of the pipe prover through relays in the control panel. When the sphere reaches the second detector switch, the system shuts down.