Implement Industry Ideas
  • Light curtain safety module

AD SRM

Article: 00121494

Light curtain safety module

The type 4 safety relay are designed with muting functions for light curtains. It provides interface module between the safety light curtains EOS4, EOS2, admiral and vision. . The safety laser PHARO and the machine control circuits are available with 2-sensor logic integrated muting. The device comes with guided contact safety relays, 2 NO contacts and PNP output to enable relay status signaling. The EDM feedback input ensures additional external contactors monitoring.

The muting time out can be selected from 0 sec, 90 min or infinite range. The device is designed in compliance with 2006/42/CE machinery directive, 2004/108/CE Electromagnetic Compatibility Directive (EMC) and 2006/95/CE Low Voltage Directive (LVD) . It features an integrated override with selectable 2-mode operation and muting enable input. The device features safety of machinery as per IEC/EN 61496-1 Ed. 2.1 and used in electro- sensitive protective equipment. The relays are used in general requirements and tests that includes IEC/TS 61496-2 Ed. 2 Safety of machinery.

Specifications

  • Options: for light curtains

Other items

In this category | In this category, (REER)